Optical fiber requirements |
Material |
Silica glass |
Profile types |
SMF (ITU-T G.652), MMF (ITU-T G.651), DSF (ITU-T G.653), NZDSF (ITU-T G.655), BIF (ITU-T G.657), EDF |
Fiber diameter |
Cladding diameter: 80 µm ~ 150 µm, Coating diameter: 100 µm ~ 1,000 µm |
Applicable fiber or cable size |
up to φ1,000 µm |
Drop cable (2.0×3.1 mm), Indoor cable (2.0×2.0 mm) |
Cleave length |
5~16 mm |
10 mm |
Standard performance |
Splice loss (typical) |
SMF: 0.02 dB, MMF: 0.01 dB, DSF: 0.04 dB, NZDSF: 0.04 dB |
Splicing cycle time (typical) |
7 sec. (Quick mode), 7.5 sec. (SMF standard mode), 8 sec. (Auto mode) |
Heating cycle time (typical) |
28 sec. |
Splice & Heat cycles |
Approx. 200 |
Fiber view & magnification |
Two CMOS cameras observation, 320X (zoom: 700X) for X or Y single axis view, 88X for both X & Y dual axis view |
Splicing programs |
Max. 300 |
Heating programs |
Max. 100 |
Functions |
Loss estimation |
Provided |
Splice image capture / Splice data storage |
64 images / 10,000 splice data |
Proof test |
1.96N (200 gf) |
Universal clamps for 250µm, 900µm tight & loose buffer fiber |
Provided |
Reversible coating clamps |
Provided |
Dual automatic independent heaters |
Provided (US patent 7,412,146) |
User-selectable heater clamp operation |
Provided |
Onboard user training video |
Provided |
Automatic arc calibration |
Automatically compensates for environmental condition changes |
Arc test |
Provided |
Display of remaining Splice & Heat cycles |
Provided (Battery mode) |
Remote interactive maintenance |
Provided |
Terminals |
DC output |
DC12 V (for JR-6) |
USB port |
USB 2.0 (mini-B type) |
Storage media |
SD / SDHC memory card |
Power supply |
AC input |
100 ~ 240V, 50 / 60 Hz (ADC-1430) |
DC input |
10 ~15 V |
Battery module |
Li-ion 11.1 V, 4,600 mAh (BU-11) |
Mechanical Parameters |
Monitor |
4.1″ touch screen color LCD display |
Size |
120(W) x 154(D) x 130(H) mm (without anti-shock rubber) |
Weight |
1.8 kg (without battery), 2.1 kg (with battery) |
Electrode life |
3,000 arc discharges |
Environment |
Operating conditions |
Altitude 0~6,000 m, Temperature -10~+50°C, Humidity 0~95% (non-condensing), Wind velocity up to 15 m/s |
Storage conditions |
Temperature -40~+80°C, Humidity 0~95% (non-condensing), Battery -20~+30°C (long term) |
Dust resistance |
Equivalent to IP5x (Operates normally after 8 hours in a dust chamber (containing dust of particle size 25 µm or below |
Water resistance |
Equivalent to IPx2 (Operates normally after being exposed to water dripping at 3mm/min. for at least 2.5 min on each of 4 surfaces tilted at 15°) |
Shock resistance |
Drop from 76cm on 5 faces (excluding top face) |