Senin - Sabtu, Jam 07.00 - 15.30, Tanggal Merah Libur +6281274087466 +6281274087466 6281274087466

Hanna HI-700 Ammonia Low Range Colorimeter

Kategori: Electronik Tester | Dilihat: 66 Kali
Harga: -
Tambah ke Wishlist

Pemesanan Juga dapat melalui :

Kode Produk: Stok Tersedia - 01-10-2024
Detail Produk

Hanna HI-700 Ammonia Low Range Colorimeter

  • Desain seukuran telapak tangan kecil
  • Akurat dari ±0,05ppm ± 5% pembacaan
  • Didedikasikan untuk satu parameter
  • Menggunakan baterai AAA tunggal
  • Auto Power Off setelah 10 menit tidak aktif
  • Timer bawaan untuk pembacaan reaksi berwaktu

Ideal for fresh water aquariums

The HI-700 Ammonia Low Range Checker is a simple, accurate and cost effective way to measure low ranges of ammonia in fresh water.

Designed as a more accurate alternative to chemical test kits, the HI-700 provides quick, accurate results in four easy steps.

HI-700 uses an adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method. The reaction between ammonia and reagents causes a yellow tint in the sample.

Ideal for

  • Freshwater Aquariums
  • Water Quality
  • Education
  • Wastewater
  • Environmental

Key features

  • Small palm-sized design
  • Accurate from ±0.05ppm ± 5% of reading
  • Dedicated to a single parameter
  • Uses a single AAA battery
  • Auto Power Off after 10 minutes in inactivity
  • Built-in timer for timed reaction readings

Four steps. One click. Instant Readout.

  1. ‘Zero’ the Checker®HC with your vial & 10ml water sample inside
  2. Take vial out and add your reagent
  3. Place your vial into your Checker®HC
  4. Press the button and read the results
Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.

Use Reagents HI-700-25 with the HI-700 Ammonia Low Range Colorimeter – Checker®HC, x 25 tests.

Use Calibration Check Set HI-700-11 with the HI-700 Ammonia Low Range Colorimeter – Checker®HC.

Specifications Hanna HI-700 Ammonia Low Range Colorimeter

Range   0.00 to 3.00 ppm NH3-N
Resolution   0.01
Accuracy @ 25°C   ±0.05 ppm ±5% of reading
Light source   LED @ 470 nm
Light Detector   Silicon photocell
Method   Adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Environment   0 to 50°C; RH max 95% non-condensing
Battery Type   (1) 1.5V AAA
Auto-off   After ten minutes of non-use
Dimensions   81.5mm x 61mm x 37.5mm
Weight   64g
Ordering Information   HI-700 Checker® is supplied with (2) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI-700A-0 reagent A and 1 bottle of HI-700B-0 reagents B), battery, instructions.
PLEASE NOTE:   In some cases, samples may contain other parameters which may interfere with results
 Interference may be caused by:   Hardness above 1 g/L
Iron
Sulphide
Glycine
Various aliphatic and aromatic amines
Organic chloramines
Acetone
Aldehydes
alcohols

Hanna HI-700 – Manual

Produk Terkait